EMS Russian Currents image 0

Corrientes rusas EMS

$1,701.00
Precio de oferta  $1,701.00 Precio habitual  $1,890.00
Ir directamente a la información del producto
EMS Russian Currents image 0

Corrientes rusas EMS

$1,701.00
Precio de oferta  $1,701.00 Precio habitual  $1,890.00
Envío calculado en el pago.
Durante el EMS, los impulsos se transmiten a través de electrodos sobre la piel para su estimulación. Estos impulsos provocan contracciones involuntarias de los músculos, fortaleciéndolos y definiéndolos. Dispositivo profesional, versátil, con 12 electrodos, digital, fácil de usar. Integra la última tecnología para desarrollar programas que le permiten estimular los músculos faciales y corporales. Temporizador programable de 15 a 40 minutos, 12 electrodos de silicona-carbono. Las corrientes rusas son corrientes de frecuencia media que trabajan isométricamente sobre los músculos, reafirmando los tejidos musculares, reduciendo la grasa localizada, acelerando el metabolismo y favoreciendo el drenaje linfático.

Hecho con cuidado

Gran valor

Detalles

Este producto está elaborado con materiales de calidad para garantizar su durabilidad y rendimiento. Diseñado pensando en su comodidad.

Key Ingredients
Benefits

Subject to confirmation of this device’s authorized indications, proposed benefits include:
• Muscle activation: Electrically induced contractions in appropriately selected muscle groups.
• Muscle conditioning: Support for professional programs focused on muscle performance.
• Temporary muscle toning and firming: Support for improved muscle tone where indicated.
Results depend on client suitability, electrode placement, settings, and treatment consistency.
EMS does not replace exercise.

Directions

1. Inspect the unit, cables, connectors, and electrodes before use.
2. Screen the client and identify suitable muscle groups and prohibited placement areas.
3. Clean and prepare the skin. Apply the compatible electrode conductive gel required by the electrode type.
4. With output switched off and intensity controls at zero, connect and position the electrodes according to a verified placement protocol.
5. Select the appropriate program, and session time.
6. Increase each active channel gradually to a comfortable level. Stimulation should not cause pain.
7. Monitor muscle response, skin contact, and client comfort throughout the session.
8. Stop for burning, pain, dizziness, palpitations, or unexpected muscle reactions.
9. Reduce every channel to zero and stop output before adjusting or removing electrodes.
10. Inspect the skin, provide aftercare, and clean the accessories.
Intensity, contraction/rest cycles, session duration, and treatment intervals require individual professional assessment within verified operating limits.

Warnings

Do not use U-CAV on clients with pacemakers, implanted defibrillators, or other implanted electronic devices.
Do not perform treatment in the presence of:
• Pregnancy.
• Active bleeding or thrombosis.
• Active infection or acute inflammation in the treatment area.
• Tumors or suspected malignant lesions in the treatment area.
• Recent fractures in the treatment area.

Do not apply cavitation above the shoulders. Treatment of the head and neck is prohibited. Avoid application over the eyes, chest, or an area containing an intrauterine device.
Clients with cardiac conditions, epilepsy, impaired sensation, recent surgery, or compromised skin require assessment to determine whether treatment is appropriate.
Possible adverse effects include skin irritation, discomfort, burns, and bruising. Stop treatment if pain, excessive heat, or an unexpected reaction occurs.
If the unit includes an electrical-stimulation function, never position electrodes across the chest, over the front or sides of the neck, over the eyes, or in a configuration that sends current through the head. Turn off the current before moving or removing electrodes.
Patients should not stop or adjust prescribed medication without consulting their prescriber.

Professional Use

For appropriately licensed professionals with education and device-specific training in electrical stimulation, anatomy, electrode placement, and client screening.
Assess medical history, muscle condition, skin integrity, sensation, implants, and contraindications before each session.
Facial electrodes require specific training and a verified facial application protocol. Their inclusion does not establish suitability for every facial area.
Pain management, circulatory conditions, edema, or rehabilitation require appropriate medical qualifications.

Storage Conditions

También podría interesarle

SUERO PASO 1 DEL PROGRAMA DE RECUPERACIÓN AVANZADA

SUERO PASO 1 DEL PROGRAMA DE RECUPERACIÓN AVANZADA

SUERO PASO 1 DEL PROGRAMA DE RECUPERACIÓN AVANZADA

$40.00 USD
Precio de oferta  $40.00 USD Precio habitual 
MASCARILLA PASO 2 DEL PROGRAMA DE RECUPERACIÓN AVANZADA

MASCARILLA PASO 2 DEL PROGRAMA DE RECUPERACIÓN AVANZADA

MASCARILLA PASO 2 DEL PROGRAMA DE RECUPERACIÓN AVANZADA

$40.00 USD
Precio de oferta  $40.00 USD Precio habitual 
Aqualite (Unidad multifuncional)

Aqualite (Unidad multifuncional)

Aqualite (Unidad multifuncional)

$390.00 USD
Precio de oferta  $390.00 USD Precio habitual 
Armesso – A.M. Age Factor

Armesso – A.M. Age Factor

Armesso – A.M. Age Factor

$145.00 USD
Precio de oferta  $145.00 USD Precio habitual